Shop

CERI L-Column3 C18

Features of the L-column3:

Improves chemical stability so that it is usable within the range of pH 1 to pH 12
Low absorptivity is at the top level for various analytes
Improvement of separation or peak shape as the pH of an eluent is flexibly selectable
A 100% aqueous eluent can be stably analyzed. (Perfect chemical stable silica)

Perfectly stable end-capping bonded phase C18, C8 PCS silica 2 Silica-based columns with the many advantages of high separation efficiency and mechanical strength are currently used for reversed-phase chromatography. Conversely, the pH range of usable eluent is limited because exposure to the alkaline solution is easily dissolved silica. L-column3 is an all-around column wherein the chemical stability (acid and alkaline resistance) of the packing material is dramatically improved by using a newly developed and highly alkaline resistant PCS silica (perfectly chemically stable silica) and perfectly stable end-capping with performance much higher than that of L-column2. L-column3 offers the possibility of improved analysis.

Ordering Information

Inner diameter (mm)Length (mm)Particle size (2µm)


Catalog no.

Particle size (3µm)


Catalog no.

Particle size (5µm)


Catalog no.

1.050
100
150
IU-813740
IU-813610
IU-813190
IU-811740
IU-811610
IU-811190
IU-812740
IU-812610
1.550
100
150


IU-811130
IU-811160
IU-811010
IU-812130
IU-812160
IU-812010
2.110
20
30
50
75
100
150
250
IU-813780
IU-813770
IU-813630
IU-813140
IU-813640
IU-813170
IU-813020
IU-811780
IU-811770
IU-811630
IU-811140
IU-811640
IU-811170
IU-811020
IU-811220


IU-812630
IU-812140

IU-812170
IU-812020
IU-812220
3.030
50
75
100
150
250
IU-823650
IU-823490
IU-823600
IU-823330

IU-821650
IU-821490
IU-821600
IU-821330
IU-821260
IU-821320



IU-822330
IU-822260
IU-822320
4.0150
250


IU-822040
IU-822320
4.630
50
75
100
150
250





IU-821060
IU-821150
IU-821460
IU-821180
IU-821070
IU-821080
IU-822060
IU-822150

IU-822180
IU-822070
IU-822080
10.0150
250


IU-842510
IU-842100
Clear
Description

L-Column3 C18

Silica-based columns with the many advantages of high separation efficiency and mechanical strength are currently used most generally for the columns for reversed-phase chromatography. On the other hand, the pH range of usable eluent is limited because exposure to the alkaline solution is easily dissolved silica.

L-column3 is an all-around column where the chemical stability (acid and alkaline resistance) of the packing materials is dramatically improved by using newly developed and highly alkaline resistant PCS silica (perfect chemical stable silica) and perfectly stable end-capping with performance much higher than that of L-column2.

L-column 3 proposes the possibility of a new analysis.

 

Base silica gel

Base silica gelPCS Silica
Average pore size12 nm
Surface area340 m2/g

L-column3 PCS Image

 

C18 (ODS)

Average particle size:2 µm, 3 µm, 5 µm
Bonded phase:C18 (Octadecyl)
End-capping:Yes
USP category:L1
Range of pH:pH 1 – pH 12

L-column3 C18(ODS) Image

 

C8 (Octyl)

Average particle size:3 µm, 5 µm
Bonded phase:C8 (Octyl)
End-capping:Yes
USP category:L7
Range of pH:pH 1 – pH 12

L-column3 C8(ODSctyl) Image

 

 

 

 

 

 

Additional Information
Particle Size

2μm, 3μm, 5μm

Length

10mm, 20mm, 30mm, 50mm, 75mm, 100mm, 150mm, 250mm, Direct Typemm, Non-direct Typemm

Internal Diameter

1.0mm, 1.5mm, 2.1mm, 3.0mm, 4.0mm, 4.6mm, 10.0mm

Pore Size

120Å

Extra Options

1 pc, none