212-204-0075
info@pyvot.tech
The Biotech knitted open tubular (KOT) reactors are made from tubing which has been knitted into a tortuous path to force the fast-moving center of the liquid stream to mix radially with the slower-moving boundary liquid layer, thereby minimizing the axial dispersion. The shape of a chromatographic peak entering the reactor is thus preserved very efficiently. To ensure stable radial mixing within the KOT, a linear flow rate of 10 cm/s or more is recommended. The KOT reactor is usually the most optimal delay element for use in analytical flow systems and is typically inserted in the flow path to create a delay line so that a reaction or other event that requires a certain time can take place. Examples of applications: efficient mixing of two fluidic streams, delay coil in a fluidic system, online derivatization of a sample with UV light, etc.
Ordering Information
Catalog no. | Length (mm) | Inner diameter (mm |
IU-3000-123 IU-3000-223 IU-3000-423 IU-3000-133 | 1m 2m 4m 10m | 0.25mm |
IU-3000-125 IU-3000-225 IU-3000-425 IU-3000-525 IU-3000-135 | 1m 2m 4m 5m 10m | 0.5mm |
IU-3000-128 IU-3000-228 IU-3000-428 IU-3000-138 | 1m 2m 4m 10m | 0.75mm |
Knitted Open Tubular (KOT) Reactor/Mixer/Delay Coil, PTFE
CONNECTION FOR MULTIPLE KOTS (I.E. TO CONNECT 2 PCS OF 10 M KOTS)
The Biotech knitted open tubular (KOT) reactors are made from tubing which has been knitted into a tortuous path to force the fast-moving centre of the liquid stream to mix radially with the slower-moving boundary liquid layer, thereby minimizing the axial dispersion. The shape of a chromatographic peak entering the reactor is thus preserved very efficiently. To ensure stable radial mixing within the KOT, a linear flow rate of 10 cm/s or more is recommended. The KOT reactor is usually the most optimal delay element for use in analytical flow systems and is typically inserted in the flow path to create a delay line so that a reaction or other event that requires a certain time can take place. Examples of applications: efficient mixing of two fluidic streams, delay coil in a fluidic system, and online derivatization of a sample with UV light, etc
Size | 1m, 2m, 4m, 5m, 10m |
---|---|
Internal Diameter | 0.25mm, 0.5mm, 0.75mm |